Chapter 3.2

Selecting machine guards

Fixed guards prevent access to hazards and must be strong, tool-removable, and not stay in place after fasteners are removed. Below we explain when, where and which guard to use in different types of situations.

If a hazard area rarely needs to be accessed (typically less than once per week), one will use so called fixed guards. A fixed guard is a cover preventing access and holding the hazard inside the machine. It is considered part of the machinery, not a type of optional accessory.

Three basic rules apply to fixed guards:

  1. They must be suitable and strong enough for the hazard expected.
  2. It must not be possible to remove them without using a tool (a coin is not a “tool”, but a standard screw driver or wrench is okay). The fasteners must not get lost after removal. So they have to stay on the guard or at the machine (see below for further details).
  3. They must not stay in place when all fasteners have been removed (as far as physically possible and not dangerous – you would not allow a 20 kg panel to just drop to the floor after loosening all bolts on it).

 

Basic rules
Basic rules for selecting machine guards

Since fixed guards are not monitored, they must only be removed when the machine is stopped safely. The standards require that they are removed under a “safe system of work” only. That is a formal procedure laid down in writing. 


The procedure should include at least the following information:

  • What are the conditions that must be met before the guard may be removed?
  • In which situations or why may the guard be removed?
  • Who may remove the guard (qualifications)?
  • Which hazards are present once the guard has been removed?
  • What is to be done before the machine can be restarted?
Axelent Safety Book Time To Spare

Why and when must guard fittings be non removable?

When the requirement for so called “no-loss fasteners” first appeared, there was much discussion about it. But their use has meanwhile been clarified by comments in (EN) ISO 14120.

No-loss fasteners need to be used when:

  • The guard needs to be removed for planned activities such as setting, troubleshooting or maintenance (performed less than once a week)
  • Loss of the fasteners is likely to occur.

No-loss fasteners are not needed when guards need to be removed only for major overhaul or transport to a new installation site. Axelent’s X-Guard system always meets the requirement, since it does not feature removable fasteners, but one needs the X-key to remove panels.

Axelent Safety Book Removable Fencing

Determining the proper height of guard fencing

The international standard requires a minimum height of 140 cm. Lower fences are easy to climb over and thus not allowed. In most cases, fences will be a lot higher.

Proper height depends on two dimensions

  • The height of the danger zone above the floor (note that the highest point may be above the top edge of the planned guard fence)
  • The horizontal distance from outside the fence to the danger zone

When these dimensions are known, you can read the required height of the fence from the table below which has been taken from (EN) ISO 13857. 
The same values are given in ANSI B11.19 Annex E.

Note: There are also minimum distances that must be kept from the inside of a mesh panel to the hazard zone.

Mesh pitch - Safety distance

Up to a slot height of 20 mm, the safety distance is ≥ 120 mm.
The same applies to square openings that are no bigger than 30 x 30 mm.

However, if the slot is more than 20 mm high and 30  to 65 mm wide a greater safety distance of 200 mm is needed.
If you need to go closer to the hazard for lack of space, use solid panelling.

Standard mesh pitches offered by Axelent:

  • 20 x 50 mm ≥ 120 mm
  • 30 x 50 mm ≥ 200 mm
Determing the height of guard fencing
A - Height of danger zone above floor | B - Height of guard | C - Horizontal safety distance to hazard zone

Selection and positioning of a protective fence

Hazard area

Determine the position of the hazard area.

Height

Determine the maximum height of the hazard area. In this case 1600 mm.

Horizontal distance

Determine the horizontal distance of the hazard zone to the fence.
In this case 400 mm.

Select correct fence height from table in the standard

EN ISO 13857, Table 2, adapted to Axelent’s fence height range (see table above).

In this case, the correct minimum fence height is 2200 mm.

Ground clearance

Check if reaching around the guard into a hazard zone is possible.

Ground clearance

If a hazard area is near the ground, it must be at least 1100 mm away, otherwise the ground clearance must be closed, e. g. with Axelent kick plate.

Part ejection or spillage

Can parts be ejected or hazardous liquids be spilled?

Part ejection or spillage

If the parts are smaller than the selected mesh pitch or liquid can be spilled, consider using
plastic or sheet metal panels.

Movable guards for frequent access

These include hinged and sliding doors, lids and flaps. They can be opened and closed quickly. But to prevent them from remaining open during operation they must be monitored.

Movable guards for frequent access

If a hazard area needs to be accessed frequently (typically more than once per week), one will use so called movable guards.

There are two main requirements for them:

  • The machine control system must monitor the guard’s condition (open/closed). It must stop any hazardous movement/situation in the machine, when it is open.
  • It must not be possible to start hazardous movements as long as the guard is open.

This is called “interlocking” because it “locks” movement of the drive(s) of the machinery depending on the condition of the guard. Most movable interlocking guards come in the shape of hinged or sliding doors, flaps and lids. 

The condition of doors is monitored by so called guard or safety switches (the proper word in standards is “interlocking device”). Essentially there are three forms of these and quite narrow rules apply to their use.  For more information, see chapter 3.6 Rules for safety switches.

Axelent Safety Book Movable Guards

Guard locking

No opening during operation

Sometimes machinery will need some time to stop when a guard is opened.

People could still reach moving parts, which is dangerous. In such cases the movable guard is fitted with an electric lock that prevents opening as long as the movement continues. This is called “guard locking”.

If an operator wants to enter the hazard zone through a locked door, he or she will have to “tell” the control system. This is done by pressing a push-button or touching a button on a touch screen. The machine will then stop or assume a safe condition. Thereafter the control system will unlock the door. Upon power failure doors with guard locking normally remain locked. This brings up the hazard of locking a person inside a machine, see section "Dealing with locking-in hazards".

Guard locking also makes sense when opening of doors during operation would cause failures. Then, however, it is not considered a safety function, because it is not installed to ensure safety. In such cases magnetic guard lockers are often used, which allow opening upon power failure.

If the machine needs some time to stop after the guard door is opened, a person may still reach a hazardous moving part. To prevent that movable guards can be fitted with door switches that prevent opening during operation. The machine will first have to be stopped, then the door can be unlocked. This is called “guard locking” and is discussed in section 3.4.

Axelent Safety Book Stop Time Machinery

No start on closing

Some designers will set the control up so the movement immediately starts (again) when a door is closed. But in general, this is not allowed.

Closing the door may only reset the interlocking. A start button will still have to be pressed. And if the area behind the door is large enough to stand in, the interlocking must additionally be reset by pressing a reset button.

If closing of the guard is to start the operation, this is referred to as an “interlocking guard with a start function”.

The limits for use of such guards are quite strict:

  • The open-time needs to be short and monitored. If the guard is open longer than programmed, restart is prevented.
  • Closing of the guard may start one short cycle only.
  • The guard must be held open safely, to prevent accidental closing (which would cause start).
  • All other guards must be interlocked, so there is no kind of unmonitored access to the hazard zone.
Sussie Knapp

Powered guards

To save time or move big heavy guards, electric, pneumatic or even hydraulic drives are sometimes employed to power guards.

Powered moving guards may present a crushing or shearing hazard. If that is the case, the guard must be fitted with additional safety equipment. Additionally, force/speed of moving guards must be kept within tight limits.

Without any additional safety devices a force of 75 N and the energy of 4 J may not be exceeded by a closing guard. This is to prevent broken limbs or even more severe injury, but 7.5 kg on your finger will  still hurt.

For this reason so called “trip bars” are used on powered guards. A trip bar is a type of rail or rubber fin that detects body parts in the way of the moving guard. The force actuated by the moving guard trips this device and the guard will stop moving or even return to its open position. 
The trip force is limited to 150 N and 10 J.

As alternatives to a trip bar one may use counter weights or another form of force reduction (slip-type coupling, pressure reduction valves, torque limiters).

Axelent Safety Book High Speed Roll Door